Electromagnetic induction: Faraday's laws and Lenz's law
Syllabus: Electromagnetic Induction
Faraday's laws, Lenz's law
Statically induced and dynamically induced emf
Self-inductance and mutual inductance, coefficient of coupling (numerical problems not needed)
Concept of Electromagnetic Induction
Electromagnetic Induction
Electromagnetic induction is the phenomenon in which an electromotive force (emf) is induced in a conductor or a coil whenever the magnetic flux linking with it changes. This phenomenon was discovered by Michael Faraday in 1831 and forms the operating principle of generators, transformers, and induction motors.
Magnetic Flux Linkage (ψ)
If a coil has N turns and a magnetic flux ϕ (in webers, Wb) passes through each turn, the total flux linkageψ is the product of the number of turns and the flux linking each turn:
ψ=Nϕ(in weber-turns, Wb-turns)
Faraday's Laws of Electromagnetic Induction
Faraday summarized the principles of electromagnetic induction into two fundamental laws:
Faraday's First Law
Whenever the magnetic flux linking a closed circuit or conductor changes, an electromotive force (emf) is induced in the conductor. If the conductor forms part of a closed circuit, an induced current flows through it for as long as the change in flux continues.
Faraday's Second Law
The magnitude of the induced emf in a coil is directly proportional to the rate of change of magnetic flux linkages with the coil.
If a coil has N turns and the magnetic flux linking it changes from ϕ1 to ϕ2 in a small time interval dt, the magnitude of the induced emf e in volts is given in differential form by:
∣e∣=dtdψ=Ndtdϕ(volts)
If the flux changes uniformly from ϕ1 to ϕ2 in time t seconds:
∣e∣=Ntϕ2−ϕ1(volts)
Lenz's Law
Lenz's Law
Proposed by Heinrich Lenz in 1834, Lenz's law states that the direction of an electromagnetically induced emf (and hence the induced current in a closed circuit) is always such that it opposes the very cause that produces it—namely, the change in magnetic flux.
Incorporating Lenz's law into Faraday's second law gives the complete mathematical expression for induced emf:
e=−Ndtdϕ(volts)
Here, the negative sign indicates that the induced emf sets up a current whose magnetic field opposes the change in the original magnetic flux ϕ.
Lenz's Law and Conservation of Energy
Lenz's law is a direct consequence of the law of conservation of energy:
Suppose the North pole of a permanent magnet is moved toward a closed coil. The magnetic flux linking the coil increases.
By Lenz's law, the induced current in the coil flows in a direction (counter-clockwise when viewed from the magnet side) that makes the near face of the coil behave like a North pole.
The two North poles repel each other. Therefore, external mechanical work must be done against this force of repulsion to push the magnet toward the coil.
This mechanical work done by the external agent is converted directly into electrical energy (and eventually dissipated as heat I2Rt in the coil). If the induced current aided the motion instead of opposing it, the magnet would accelerate on its own without any energy input, violating conservation of energy.
Types of Induced EMF
An emf can be induced in a conductor by changing the flux linkage in two fundamental ways:
Code
Induced EMF
|
+---------------+---------------+
| |
Dynamically Induced EMF Statically Induced EMF
(Conductor moves OR (Both conductor and magnet
field moves physically) are stationary; flux magnitude
varies with time)
|
+---------------+---------------+
| |
Self-Induced EMF Mutually Induced EMF
(In the same coil) (In a neighboring coil)
Dynamically Induced EMF
Dynamically Induced EMF
When the magnetic field is stationary (constant in time) and the conductor moves across the magnetic flux lines—or when the conductor is stationary and the magnetic field system moves physically past it—the emf induced in the conductor is called dynamically induced emf (or motional emf). Examples include DC generators and AC synchronous generators (alternators).
Expression for Dynamically Induced EMF:
Consider a straight conductor of active length l meters moving with a uniform velocity v m/s in a uniform magnetic field of flux density B tesla (Wb/m2).
Let the conductor move in a direction making an angle θ with the direction of the magnetic field lines.
In a small time interval dt, the conductor moves a distance dx=vdt. The component of displacement perpendicular to the magnetic field is dx⊥=vdtsinθ.
The area swept by the conductor perpendicular to the flux lines in time dt is:
dA=l⋅vsinθdt
Therefore, the magnetic flux cut by the conductor in time dt is:
dϕ=B⋅dA=Blvsinθdt
By Faraday's law, the magnitude of the induced emf in the single conductor is:
e=dtdϕ=Blvsinθ(volts)
Case 1 (Conductor moves parallel to the field, θ=0∘):sin0∘=0⟹e=0 V. No flux lines are cut.
Case 2 (Conductor moves perpendicular to the field, θ=90∘):sin90∘=1⟹e=Blv V (maximum induced emf).
Fleming's Right-Hand Rule
The direction of dynamically induced emf is found using Fleming's Right-Hand Rule: Hold the thumb, forefinger, and middle finger of the right hand mutually perpendicular to one another. If the Forefinger points in the direction of the magnetic Field (North to South), and the Thumb points in the direction of Motion of the conductor (relative to the field), then the Middle finger points in the direction of the Induced EMF (or current).
Statically Induced EMF
Statically Induced EMF
When both the conductor (coil) and the magnetic field system are completely stationary, and the magnetic flux linking the coil is changed purely by varying the magnitude of the electric current producing the flux, the induced emf is called statically induced emf (or transformer emf). An example is the electrical transformer.
Statically induced emf is further classified into two types:
Self-induced emf: Induced in a coil due to the change of flux produced by its own current.
Mutually induced emf: Induced in a coil due to the change of flux produced by a current flowing in a neighboring magnetically coupled coil.
Comparison: Dynamically vs. Statically Induced EMF
Feature
Dynamically Induced EMF
Statically Induced EMF
Physical movement
Relative physical motion exists between conductor and magnetic field
Both conductor and magnetic field system remain stationary
Cause of flux change
Conductor physically cuts across magnetic flux lines
Magnitude of current producing the flux varies with time
Formula
e=Blvsinθ
e=−Ndtdϕ
Rule for direction
Fleming's Right-Hand Rule
Lenz's Law
Practical example
DC generator, AC alternator
Transformer
Summary
Faraday's First Law: A changing magnetic flux linking a conductor induces an emf in it.
Faraday's Second Law & Lenz's Law:e=−Ndtdϕ, where the negative sign shows opposition to the change in flux.
Dynamically induced emf:e=Blvsinθ, produced by relative motion between conductor and field.
Statically induced emf: Produced by time-varying current in a stationary coil system.
Self-inductance, mutual inductance and coefficient of coupling
Self-Inductance (L)
Self-Induced EMF
When a time-varying current i flows through a coil of N turns, it sets up a time-varying magnetic flux ϕ through the coil itself. By Faraday's law, this changing flux induces an emf in the very same coil that opposes the change in current. This emf is called self-induced emf.
Self-Inductance (Coefficient of Self-Induction)
Self-inductance (L) is the property of a coil by virtue of which it opposes any change in the magnitude or direction of electric current flowing through it by inducing an emf in itself. The SI unit of inductance is the henry (H).
Expressions for Self-Inductance
Assuming the magnetic core has constant permeability (no magnetic saturation), the flux ϕ is directly proportional to the current i:
In terms of flux linkage per unit current:ψ=Nϕ∝i⟹Nϕ=LiL=iNϕ(henrys, H)Definition: A coil has a self-inductance of 1 henry if a current of 1 ampere flowing through it produces a flux linkage of 1 weber-turn.
In terms of self-induced emf:
By Faraday's law, the magnitude of self-induced emf is:
eL=Ndtdϕ=dtd(Nϕ)=dtd(Li)
Since L is constant for an air core or unsaturated magnetic core:
eL=Ldtdi(volts)(Taking opposition into account, eL=−Ldtdi.)Definition: A coil has a self-inductance of 1 henry if a current changing at the rate of 1 ampere per second induces an emf of 1 volt in the coil.
In terms of physical dimensions and magnetic reluctance:
From magnetic circuit theory, flux ϕ=ReluctanceMMF=SNi, where reluctance S=μ0μrAl.
Substituting ϕ into L=iNϕ:
L=iN(SNi)=SN2L=lμ0μrAN2(henrys, H)
where N is the number of turns, A is the cross-sectional area of the core (m2), l is the mean length of the magnetic path (m), μ0=4π×10−7 H/m, and μr is the relative permeability of the core.
Mutual Inductance (M)
Mutually Induced EMF
Consider two coils, Coil 1 (having N1 turns) and Coil 2 (having N2 turns), placed close to each other so that a portion of the magnetic flux produced by one coil links with the other:
When a time-varying current i1 flows in Coil 1, it produces a total flux ϕ1. A part of this flux, denoted ϕ12, links with Coil 2. As i1 changes, ϕ12 changes, inducing an emf eM2 in Coil 2. This is called mutually induced emf.
Mutual Inductance (Coefficient of Mutual Induction)
Mutual inductance (M) between two coils is defined as the property by which a change of current in one coil induces an emf in the neighboring coil. Its SI unit is also the henry (H).
Expressions for Mutual Inductance
In terms of mutual flux linkage per unit current:
The flux linkage in Coil 2 due to current i1 in Coil 1 is N2ϕ12, which is proportional to i1:
N2ϕ12=Mi1⟹M=i1N2ϕ12(H)
Similarly, if current i2 flows in Coil 2 and produces flux ϕ21 linking Coil 1:
M=i2N1ϕ21(H)
For a linear (unsaturated) magnetic medium, M12=M21=M.
In terms of mutually induced emf:
By Faraday's second law, the magnitude of mutually induced emf in Coil 2 when current i1 changes in Coil 1 is:
eM2=N2dtdϕ12=dtd(N2ϕ12)=dtd(Mi1)eM2=Mdtdi1(volts)Definition: Two coils have a mutual inductance of 1 henry if a current changing at the rate of 1 ampere per second in one coil induces an emf of 1 volt in the other coil.
In terms of magnetic circuit parameters:
If both coils are wound on the same core of reluctance S=μ0μrAl and all the flux of Coil 1 links Coil 2 (ϕ12=ϕ1=SN1i1):
M=i1N2(SN1i1)=SN1N2=lμ0μrAN1N2(H)
Coefficient of Coupling (k)
Coefficient of Coupling
The coefficient of coupling (k) between two magnetically coupled coils is defined as the fraction of the total magnetic flux produced by one coil that actually links with the second coil. It is a dimensionless number between 0 and 1 (0≤k≤1).
Derivation of M=kL1L2:
Let current i1 in Coil 1 (N1 turns) produce total flux ϕ1. The self-inductance of Coil 1 is:
L1=i1N1ϕ1— (Equation 1)
If k is the coefficient of coupling, the flux linking Coil 2 is ϕ12=kϕ1. Therefore, the mutual inductance is:
M=i1N2ϕ12=i1N2(kϕ1)— (Equation 2)
Similarly, let current i2 in Coil 2 (N2 turns) produce total flux ϕ2. The self-inductance of Coil 2 is:
L2=i2N2ϕ2— (Equation 3)
A fraction k of ϕ2 links with Coil 1, so ϕ21=kϕ2. Expressing M from Coil 2 to Coil 1:
M=i2N1ϕ21=i2N1(kϕ2)— (Equation 4)
Multiplying Equation 2 and Equation 4 together:
M×M=(i1kN2ϕ1)(i2kN1ϕ2)=k2(i1N1ϕ1)(i2N2ϕ2)
Substituting L1 and L2 from Equations 1 and 3:
M2=k2L1L2M=kL1L2⟺k=L1L2M
Special Cases of Coupling:
Tightly coupled coils (k≈1): Nearly 100% of the flux of one coil links the other (e.g., transformer windings wound on a common iron core, where k≈0.98 to 0.99). For ideal coupling (k=1), Mmax=L1L2.
Loosely coupled coils (k<0.5): Only a small fraction of flux links the second coil (e.g., air-core radio-frequency coils separated in space).
Magnetically isolated coils (k=0): Coils are placed far apart or perpendicular to each other so that ϕ12=0 and M=0.
Comparison: Self-Inductance vs. Mutual Inductance
Parameter
Self-Inductance (L)
Mutual Inductance (M)
Number of coils
Associated with a single coil
Associated with a pair of magnetically coupled coils
Flux linkage formula
L=iNϕ
M=i1N2ϕ12=i2N1ϕ21
Induced EMF formula
eL=Ldtdi
eM2=Mdtdi1
Physical formula
L=SN2=lμ0μrAN2
M=SkN1N2=kL1L2
Summary
Self-inductance:L=iNϕ=SN2, and self-induced emf eL=Ldtdi.
Mutual inductance:M=i1N2ϕ12, and mutually induced emf eM2=Mdtdi1.
Coefficient of coupling:k=ϕ1ϕ12=L1L2M, with 0≤k≤1.
Alternating current fundamentals: Generation and waveform representation
Syllabus: Alternating Current Fundamentals
Generation of alternating voltages
Representation of sinusoidal waveforms: frequency, period, average value, RMS value and form factor - numerical problems
Alternating Quantity vs. Direct Quantity
Direct Current (DC): An electric current or voltage whose magnitude and direction (polarity) remain constant with time (e.g., output of a storage battery).
Alternating Current (AC): An electric current or voltage whose magnitude changes continuously with time and whose direction reverses periodically at regular intervals. The most standard and widely used alternating waveform is the sinusoidal waveform (sine wave).
Generation of Alternating Voltage
An alternating voltage is generated based on Faraday's law of electromagnetic induction either by rotating a rectangular coil with constant angular velocity inside a uniform stationary magnetic field, or by rotating a magnetic field inside a stationary set of coils (as in large commercial alternators).
Code
N-Pole S-Pole
+------+ (b) +------+
| | o | |
| | / | |
| B | ---> O omega | B |
| | / | |
| | o | |
+------+ (a) +------+
Axis of coil rotation
Derivation of the Sinusoidal EMF Equation:
Consider a rectangular coil of N turns and cross-sectional area A m2 placed in a uniform magnetic field of flux density B tesla (Wb/m2).
Let the coil rotate counter-clockwise at a uniform angular velocity of ω radians per second (rad/s).
At time t=0, assume the plane of the coil is perpendicular to the magnetic field lines (i.e., the normal to the coil plane is parallel to B, so angle θ=0). At this instant, the magnetic flux passing through the coil is maximum:
Φm=B⋅A(webers)
After time t seconds, the coil has rotated through an angle θ=ωt radians. The component of magnetic flux perpendicular to the plane of the coil at instant t is:
ϕ(t)=BAcosθ=Φmcos(ωt)
By Faraday's law of electromagnetic induction, the instantaneous emf e induced in the coil of N turns is:
e=−Ndtdϕ=−Ndtd(Φmcosωt)e=−NΦm(−ωsinωt)=ωNΦmsin(ωt)
The induced emf reaches its maximum (peak) value Em when sin(ωt)=1, i.e., when θ=ωt=90∘ (at this position, the plane of the coil is parallel to the magnetic field lines and the coil sides cut the flux lines at maximum rate):
Em=ωNΦm=2πfNBA(volts)
Substituting Em gives the standard equation for instantaneous alternating emf:
e(t)=Emsin(ωt)=Emsinθ(volts)
Key Terminology of Sinusoidal Waveforms
A general sinusoidal voltage or current is written as:
v(t)=Vmsin(ωt+ϕ)ori(t)=Imsin(ωt+ϕ)
Instantaneous Value (v or i): The value of an alternating quantity at any particular instant of time t. It is denoted by lowercase letters (e,v,i).
Maximum Value / Peak Value / Amplitude (Vm or Im): The highest positive or negative value attained by an alternating quantity during one half-cycle. The peak-to-peak value is Vp−p=2Vm.
Cycle: One complete set of positive and negative values of an alternating quantity before it repeats itself. One complete cycle corresponds to 360∘ or 2π electrical radians.
Time Period (T): The time taken in seconds by an alternating quantity to complete one full cycle.
Frequency (f): The number of cycles completed per second. Its SI unit is hertz (Hz) (or cycles/second).
f=T1andT=f1(In India, the standard AC power supply frequency is f=50 Hz, giving T=501=0.02 s=20 ms.)
Angular Frequency (ω): The rate of change of angle in radians per second. Since one cycle equals 2π radians in time T:
ω=T2π=2πf(rad/s)
Electrical Angle vs. Mechanical Angle: In an AC machine having P magnetic poles, one complete mechanical revolution (360∘ mechanical) produces P/2 complete electrical cycles. Therefore:
θelectrical=2Pθmechanicalandf=120PN
where N is the rotational speed in revolutions per minute (rpm).
Worked Example 1
Problem: A rectangular coil of 200 turns having dimensions 30 cm×20 cm is rotated at a constant speed of 1500 rpm in a uniform magnetic field of flux density 0.1 T. Calculate:
(a) Frequency and time period of the generated voltage,
(b) Maximum value of induced emf,
(c) Equation of the instantaneous emf, and
(d) Instantaneous emf at t=2 ms from the start of the cycle.
Instantaneous sinusoidal emf: e(t)=Emsin(ωt), where Em=2πfNBA.
Frequency f=1/T and angular frequency ω=2πf rad/s.
For a P-pole machine rotating at N rpm, f=120PN Hz.
Average value, RMS value, form factor and peak factor
Average Value (Iavg or Vavg)
Definition of Average Value
The average value of an alternating current is defined as that steady (DC) current which transfers across any circuit the same amount of electric charge in a given time interval as is transferred by the alternating current in the same time interval.
For a symmetrical alternating waveform (like a pure sine wave), the positive half-cycle is identical in area to the negative half-cycle. Hence, the average value over one complete cycle is always zero. Therefore, for symmetrical waveforms, the average value is always defined over a half-cycle (from θ=0 to θ=π).
In general, for a waveform i(θ) over an interval of base length B:
Iavg=Base length of the intervalArea under the curve over the interval=B1∫0Bi(θ)dθ
Derivation of Average Value for a Sinusoidal Waveform:
Consider a sinusoidal current i=Imsinθ.
Integrating over one positive half-cycle (θ=0 to θ=π, so base B=π):
Iavg=π1∫0πImsinθdθ=πIm[−cosθ]0π
Substituting the limits (cosπ=−1 and cos0=1):
Iavg=πIm[−(−1)−(−1)]=π2Im≈0.637Im
Similarly, for a sinusoidal voltage:
Vavg=π2Vm≈0.637Vm
Root Mean Square (RMS) or Effective Value (Irms or Vrms)
Definition of RMS (Effective) Value
The RMS (Root Mean Square) or effective value of an alternating current is defined as that steady (DC) current which, when flowing through a given resistance for a given time, produces the exact same amount of heat energy as is produced by the alternating current when flowing through the same resistance for the same time.
(Note: All standard AC voltmeters and ammeters are calibrated to read RMS values, and domestic supply ratings like "230 V AC" always specify the RMS value unless stated otherwise.)
Mathematically, for a periodic waveform i(θ) of period T (or 2π radians):
Irms=T1∫0T[i(t)]2dt=2π1∫02π[i(θ)]2dθ
Derivation of RMS Value for a Sinusoidal Waveform:
Consider a sinusoidal current i=Imsinθ. Because [i(θ)]2=Im2sin2θ is identical over both positive and negative half-cycles, the mean of the square over a half-cycle (0 to π) is the same as over a full cycle (0 to 2π).
Taking the integral over 0 to π:
Irms2=π1∫0πIm2sin2θdθ
Using the trigonometric identity sin2θ=21−cos2θ:
Irms2=2πIm2∫0π(1−cos2θ)dθ=2πIm2[θ−2sin2θ]0π
Since sin(2π)=0 and sin(0)=0:
Irms2=2πIm2(π−0)=2Im2
Taking the square root on both sides:
Irms=2Im≈0.707Im
Similarly, for a sinusoidal voltage:
Vrms=2Vm≈0.707Vm
Form Factor (Kf) and Peak (Crest) Factor (Kp)
Form Factor (Kf)
The form factor of an alternating waveform is defined as the ratio of its RMS value to its average value:
Form Factor (Kf)=Average ValueRMS Value=IavgIrms
Problem: An alternating voltage is given by v(t)=325.27sin(314t) V. Find:
(a) Maximum voltage, (b) RMS voltage, (c) Average voltage, (d) Frequency, (e) Time period, and (f) Form factor.
Solution:
Compare v(t)=325.27sin(314t) with v(t)=Vmsin(ωt):
(a) Maximum voltage: Vm=325.27 V
Angular frequency: ω=314 rad/s
(b) RMS voltage:
Vrms=2Vm=1.4142325.27=230 V
(c) Average voltage over a half-cycle:
Vavg=π2Vm=0.637×325.27=207.2 V
Problem: Find the average value, RMS value, and form factor of a periodic voltage waveform that increases linearly from 0 V to 100 V in 0.01 s and then drops instantly to 0 V, repeating with a time period T=0.01 s (a sawtooth waveform).
Solution:
Write the equation of the waveform for one period (0≤t≤T):
With Vm=100 V and T=0.01 s, the straight line through the origin is:
v(t)=TVmt
Calculate the average value (Vavg):Vavg=T1∫0T(TVmt)dt=T2Vm[2t2]0T=2Vm=2100=50 V
Calculate the RMS value (Vrms):Vrms=T1∫0T(TVmt)2dt=T3Vm2[3t3]0T=3Vm=1.732100=57.74 V
Calculate the form factor (Kf):Kf=VavgVrms=5057.74=1.155
Answer:Vavg=50 V, Vrms=57.74 V, Kf=1.155.
Summary
For a sine wave: Iavg=π2Im=0.637Im and Irms=2Im=0.707Im.
Form factor Kf=AverageRMS=1.11 (for sine wave).
Peak factor Kp=RMSPeak=1.414 (for sine wave).
Phasor representation of sinusoidal quantities
Syllabus: AC Circuits – Phasor Representation
Phasor representation of sinusoidal quantities
Trigonometric, Rectangular, Polar and complex forms
Concept of a Phasor
Phasor
A phasor is a directed line segment (rotating vector) rotating counter-clockwise in the complex plane with a constant angular velocity ω equal to the angular frequency of the sinusoidal quantity it represents.
The length of the phasor represents either the maximum value (Vm) or, by standard engineering convention, the RMS value (V=Vm/2) of the sinusoid.
The angle (ϕ) that the phasor makes with the positive real (reference) axis at t=0 represents the phase angle of the sinusoid.
The projection of a rotating phasor of length Vm on the vertical (imaginary) axis at any instant t gives the instantaneous value v(t)=Vmsin(ωt+ϕ).
Phase and Phase Difference
Phase
The phase of an alternating quantity at any instant is the fraction of a time period (or the angle in radians/degrees) that has elapsed since the quantity last passed through its zero reference position in the positive direction. In v(t)=Vmsin(ωt+ϕ1), the argument (ωt+ϕ1) is the phase at time t, and ϕ1 is the initial phase angle at t=0.
Phase Difference
When two alternating quantities of the same frequencyω are given by:
v(t)=Vmsin(ωt+ϕ1)andi(t)=Imsin(ωt+ϕ2)
the difference between their phase angles, ϕ=ϕ1−ϕ2, is called the phase difference, which remains constant with time:
In Phase (ϕ1−ϕ2=0∘): Both quantities pass through their zero and peak values of the same polarity at the exact same instant. Their phasors are collinear and point in the same direction.
Leading (ϕ1>ϕ2): Voltage v(t) reaches its positive zero and positive peak earlier in time by angle ϕ=ϕ1−ϕ2 than current i(t). We say v leads i by angle ϕ. In a phasor diagram (where rotation is counter-clockwise), the phasor V lies ahead of I in the counter-clockwise direction by angle ϕ.
Lagging (ϕ1<ϕ2): Current i(t) reaches its peak behind voltage v(t) by angle ϕ. We say i lags behind v by angle ϕ (located clockwise relative to V).
Code
Imaginary (+j)
^
| / V (Leads I by phi)
| /
| / phi1
| / \ phi2
-------+--o----------------> Real (Reference Axis)
| \
| \ I (Lags V)
Mathematical Forms of a Phasor
Using the RMS value V=Vm/2 and phase angle ϕ, a sinusoidal quantity v(t)=2Vsin(ωt+ϕ) is represented as a complex phasor V in four equivalent mathematical forms:
Polar Form:
Specifies the RMS magnitude V and the phase angle ϕ (usually in degrees):
V=V∠ϕ
Exponential (Complex) Form:
Based on Euler's identity ejϕ=cosϕ+jsinϕ, where j=−1 is the imaginary operator in electrical engineering (used instead of i to avoid confusion with current):
V=Vejϕ
Trigonometric Form:
Expanding the exponential form using Euler's identity:
V=V(cosϕ+jsinϕ)
Rectangular (Cartesian) Form:
Expresses the phasor in terms of its real (in-phase) component a and imaginary (quadrature) component b in the complex plane:
V=a+jb
where:
a=Vcosϕandb=Vsinϕ
Conversions Between Rectangular and Polar Forms
Polar to Rectangular (V∠ϕ⟶a+jb):a=Vcosϕ,b=Vsinϕ
Rectangular to Polar (a+jb⟶V∠ϕ):V=a2+b2,ϕ=tan−1(ab)(Care must be taken with the signs of a and b to place ϕ in the correct quadrant: if a<0 and b>0, ϕ=180∘−tan−1∣b/a∣; if a<0 and b<0, ϕ=−180∘+tan−1∣b/a∣.)
Properties of the j-Operator and Phasor Arithmetic
Properties of j:
j=−1=1∠90∘ (multiplying a phasor by j rotates it counter-clockwise by 90∘).
j2=−1=1∠180∘
j3=−j=1∠270∘=1∠−90∘
j4=+1=1∠0∘
j1=−j=1∠−90∘ (dividing by j or multiplying by −j rotates a phasor clockwise by 90∘).
Addition and Subtraction (best done in Rectangular Form):
If V1=a1+jb1 and V2=a2+jb2:
V1±V2=(a1±a2)+j(b1±b2)
Multiplication and Division (best done in Polar Form):
If V1=V1∠ϕ1 and V2=V2∠ϕ2:
V1⋅V2=(V1V2)∠(ϕ1+ϕ2)V2V1=(V2V1)∠(ϕ1−ϕ2)
Worked Example 1
Problem: Express the sinusoidal voltage v(t)=141.42sin(314t−30∘) V as an RMS phasor in Polar, Exponential, Trigonometric, and Rectangular forms.
Solution:
Find the RMS magnitude and phase angle:
Peak voltage Vm=141.42 V
RMS voltage V=2141.42=100 V
Phase angle ϕ=−30∘=−6π rad
Write the four forms:
Polar form:V=100∠−30∘ V
Exponential form:V=100e−j30∘ V=100e−jπ/6 V
Trigonometric form:V=100[cos(−30∘)+jsin(−30∘)]=100(cos30∘−jsin30∘) V
Rectangular form:a=100cos(−30∘)=100×0.866=86.6 Vb=100sin(−30∘)=100×(−0.5)=−50 VV=(86.6−j50) V
Problem: Two alternating currents entering a node are given by i1(t)=102sin(ωt+30∘) A and i2(t)=202sin(ωt−45∘) A. Find the total current i(t)=i1(t)+i2(t) in time-domain sinusoidal form.
Solution:
Convert i1(t) and i2(t) to RMS Polar and Rectangular forms:
I1=10∠30∘=10(cos30∘+jsin30∘)=8.66+j5.0 A
I2=20∠−45∘=20(cos45∘−jsin45∘)=14.14−j14.14 A
Add the two phasors in rectangular form:I=I1+I2=(8.66+14.14)+j(5.0−14.14)=22.80−j9.14 A
Convert I back to polar form:I=(22.80)2+(−9.14)2=519.84+83.54=603.38=24.56 Aϕ=tan−1(22.80−9.14)=−21.84∘I=24.56∠−21.84∘ A
Write the time-domain expression (Im=2I):i(t)=24.562sin(ωt−21.84∘)=34.73sin(ωt−21.84∘) A
Answer:i(t)=34.73sin(ωt−21.84∘) A.
Summary
A sinusoid v(t)=2Vsin(ωt+ϕ) is represented as an RMS phasor V=V∠ϕ=V(cosϕ+jsinϕ)=a+jb.
Use rectangular form for addition/subtraction and polar form for multiplication/division.
Multiplying by j advances the phase by +90∘; multiplying by −j (or dividing by j) retards the phase by −90∘.
Analysis of simple AC circuits: Purely resistive, inductive and capacitive circuits
Syllabus: Analysis of Simple AC Circuits
Purely resistive, inductive & capacitive circuits
Inductive and capacitive reactance, concept of impedance - numerical problems
1. AC Circuit with a Pure Resistor (R)
Consider an AC voltage source v(t)=Vmsin(ωt) connected across a pure resistor of resistance R ohms.
Current Equation: By Ohm's law, the instantaneous current is:
i(t)=Rv(t)=RVmsin(ωt)=Imsin(ωt)
where peak current Im=RVm and RMS current I=RV.
Phase Relationship: Comparing v(t)=Vmsin(ωt) and i(t)=Imsin(ωt), the phase angle between voltage and current in a pure resistor is zero (ϕ=0∘). Voltage and current are in phase.
Phasor Relation and Complex Impedance:
If V=V∠0∘, then I=I∠0∘.
ZR=IV=R∠0∘=R+j0(Ω)
Instantaneous and Average Power:p(t)=v(t)⋅i(t)=(Vmsinωt)(Imsinωt)=VmImsin2(ωt)
Using sin2(ωt)=21−cos(2ωt) and VmIm=2VI:
p(t)=VI(1−cos2ωt)=VI−VIcos(2ωt)
Since the average of cos(2ωt) over a full cycle is zero, the average power consumed over a cycle is:
P=VI=I2R=RV2(watts, W)
2. AC Circuit with a Pure Inductor (L)
Consider an AC voltage source v(t)=Vmsin(ωt) connected across a pure (lossless, R=0) inductor of inductance L henrys.
Current Equation: By KVL and Faraday's law, the applied voltage equals the self-induced voltage drop across the inductor:
v(t)=Ldtdi=Vmsin(ωt)
Integrating both sides with respect to t:
i(t)=LVm∫sin(ωt)dt=−ωLVmcos(ωt)
Using −cos(ωt)=sin(ωt−90∘):
i(t)=Imsin(ωt−90∘)=Imsin(ωt−2π)
where the peak current is Im=ωLVm=XLVm.
Inductive Reactance (XL):
The opposition offered by an inductor to the flow of alternating current is called inductive reactance (XL), measured in ohms (Ω):
XL=ωL=2πfL(Ω)
XL is directly proportional to frequency f. For DC (f=0), XL=0Ω, so a pure inductor acts as a short circuit to steady DC.
Phase Relationship: In a pure inductor, the current lags behind the applied voltage by 90∘ (π/2 rad), or equivalently, voltage leads current by 90∘.
Phasor Relation and Complex Impedance:
If V=V∠0∘, then I=I∠−90∘.
ZL=IV=I∠−90∘V∠0∘=XL∠90∘=jXL=jωL(Ω)
Instantaneous and Average Power:p(t)=v(t)⋅i(t)=(Vmsinωt)(−Imcosωt)=−2VmImsin(2ωt)=−VIsin(2ωt)
The instantaneous power is a double-frequency sine wave (2f) that alternates equally between positive (energy absorbed from source to build magnetic field, 21Li2) and negative (energy returned completely to the source when magnetic field collapses). Therefore, the average power consumed over a complete cycle is zero:
P=0 W
3. AC Circuit with a Pure Capacitor (C)
Consider an AC voltage source v(t)=Vmsin(ωt) connected across a pure capacitor of capacitance C farads.
Current Equation: The instantaneous charge on the capacitor is q(t)=Cv(t), so the current is:
i(t)=dtdq=Cdtdv=Cdtd(Vmsinωt)=ωCVmcos(ωt)
Using cos(ωt)=sin(ωt+90∘):
i(t)=Imsin(ωt+90∘)=Imsin(ωt+2π)
where the peak current is Im=ωCVm=1/(ωC)Vm=XCVm.
Capacitive Reactance (XC):
The opposition offered by a capacitor to the flow of alternating current is called capacitive reactance (XC), measured in ohms (Ω):
XC=ωC1=2πfC1(Ω)
XC is inversely proportional to frequency f. For DC (f=0), XC=∞Ω, so a capacitor acts as an open circuit to steady DC.
Phase Relationship: In a pure capacitor, the current leads the applied voltage by 90∘ (π/2 rad), or equivalently, voltage lags behind current by 90∘.
Phasor Relation and Complex Impedance:
If V=V∠0∘, then I=I∠+90∘.
ZC=IV=I∠90∘V∠0∘=XC∠−90∘=−jXC=jωC1(Ω)
Instantaneous and Average Power:p(t)=v(t)⋅i(t)=(Vmsinωt)(Imcosωt)=2VmImsin(2ωt)=VIsin(2ωt)
Energy stored in the electrostatic field (21Cv2) during one quarter-cycle is returned completely to the source during the next quarter-cycle. Hence, the average power consumed over a complete cycle is zero:
P=0 W
Concept of Impedance (Z)
In general AC circuits containing resistance R and reactance X, impedance (Z) is defined as the complex ratio of the voltage phasor V to the current phasor I:
Z=IV=R+jX=Z∠ϕ(Ω)
where the magnitude of impedance is Z=R2+X2 and the phase angle is ϕ=tan−1(X/R).
Comparison of Pure R, Pure L, and Pure C Circuits
Parameter
Pure Resistor (R)
Pure Inductor (L)
Pure Capacitor (C)
Opposition to AC
Resistance R (independent of f)
Reactance XL=2πfL (∝f)
Reactance XC=2πfC1 (∝f1)
Complex Impedance (Z)
R=R∠0∘
+jXL=XL∠+90∘
−jXC=XC∠−90∘
Phase of I relative to V
I is in phase with V (ϕ=0∘)
I lags V by 90∘ (ϕ=+90∘)
I leads V by 90∘ (ϕ=−90∘)
Average Power (P)
P=VI=I2R
P=0 W
P=0 W
Worked Example 1
Problem: A pure inductor of L=0.15 H is connected across a 230 V,50 Hz AC supply. Find: (a) Inductive reactance, (b) RMS current, (c) Peak current, and (d) Equation for instantaneous current if v(t)=2302sin(314t) V.
(d) Since current lags voltage by 90∘ in a pure inductor:
i(t)=6.90sin(314t−90∘) A
Answer:XL=47.12Ω, I=4.88 A, Im=6.90 A, i(t)=6.90sin(314t−90∘) A.
Worked Example 2
Problem: A 50μF capacitor is connected across a 200 V,50 Hz single-phase AC supply. Calculate: (a) Capacitive reactance, (b) RMS current, and (c) Maximum power delivered by the source at any instant.
(c) Instantaneous power is p(t)=VIsin(2ωt). Its maximum value (when sin2ωt=1) is:
Pinst, max=VI=200×3.14=628 W(Note: Average power over a full cycle is 0 W.)
Answer:XC=63.66Ω, I=3.14 A, Pinst, max=628 W.
Summary
Pure R: ZR=R∠0∘, I in phase with V, P=VI.
Pure L: ZL=jXL=ωL∠90∘, I lags V by 90∘, P=0.
Pure C: ZC=−jXC=ωC1∠−90∘, I leads V by 90∘, P=0.
RL, RC and RLC series AC circuits
Syllabus: RL, RC and RLC Series Circuits
RL, RC and RLC series circuits
Power factor, active, reactive and apparent power - simple numerical problems
1. Series RL Circuit
Consider a resistor R and an inductor L connected in series across an AC supply v(t)=Vmsin(ωt). Since the circuit is in series, the same current I=I∠0∘ (taken as the reference phasor) flows through both elements.
Code
I ---> V_R V_L
+-----------/\/\/\-------uuuuuu-------+
| R L |
(~) V |
| |
+-------------------------------------+
Component Voltage Phasors:
Voltage drop across R: VR=IR∠0∘=VR+j0 (in phase with I).
Voltage drop across L: VL=I(jXL)=IXL∠+90∘=jVL (leads I by 90∘).
Total Supply Voltage and Voltage Triangle:
By Kirchhoff's Voltage Law (KVL) in phasor form:
V=VR+VL=VR+jVL=I(R+jXL)
Magnitude of supply voltage:
V=VR2+VL2=IR2+XL2
Impedance (Z) and Impedance Triangle:Z=IV=R+jXL=Z∠+ϕ
where magnitude Z=R2+XL2 and phase angle ϕ=tan−1(RXL)=tan−1(VRVL).
Phase Relationship: Since ϕ is positive (0∘<ϕ<90∘), the supply voltage V leads the current I by angle ϕ, or current I lags behind voltage V by angle ϕ.
Code
Voltage Triangle (RL) Impedance Triangle (RL)
/| /|
V / | V_L = I*X_L Z / | X_L
/ | / |
/phi| /phi|
+----+ +----+
V_R = I*R R
2. Series RC Circuit
Consider a resistor R and a capacitor C connected in series carrying reference current I=I∠0∘.
Component Voltage Phasors:
Voltage drop across R: VR=IR∠0∘=VR (in phase with I).
Voltage drop across C: VC=I(−jXC)=IXC∠−90∘=−jVC (lags behind I by 90∘).
Total Supply Voltage:V=VR+VC=VR−jVC=I(R−jXC)
Magnitude:
V=VR2+VC2=IR2+XC2
Impedance (Z):Z=IV=R−jXC=Z∠−ϕ
where magnitude Z=R2+XC2 and phase angle Magnitude ϕ=tan−1(RXC)=tan−1(VRVC) (or θZ=tan−1(−XC/R)=−ϕ).
Phase Relationship: The supply voltage V lags behind I by angle ϕ, or current I leads the supply voltage V by angle ϕ (0∘<ϕ<90∘).
3. Series RLC Circuit
Consider a resistor R, an inductor L, and a capacitor C connected in series across an AC supply V, carrying a common reference current I=I∠0∘.
Code
I ---> V_R V_L V_C
+----------/\/\/\----uuuuuu------||------+
| R L C |
(~) V |
+----------------------------------------+
Phasor KVL Equation:
VR=IR (along +x axis, in phase with I)
VL=+jIXL (along +j axis, leading I by 90∘)
VC=−jIXC (along −j axis, lagging I by 90∘)
Since VL and VC are 180∘ out of phase with each other, they partially or fully cancel:
V=VR+VL+VC=VR+j(VL−VC)=I[R+j(XL−XC)]
Magnitude of supply voltage:
V=VR2+(VL−VC)2
Total Complex Impedance (Z):Z=R+j(XL−XC)=R+jX=Z∠ϕ
where net reactance is X=XL−XC, impedance magnitude is:
Z=R2+(XL−XC)2
and phase angle is:
ϕ=tan−1(RXL−XC)=tan−1(VRVL−VC)
Three Operating Cases of an RLC Series Circuit:
Condition
Net Reactance (X=XL−XC)
Circuit Nature
Phase of Current I relative to V
Power Factor (cosϕ)
Case 1: XL>XC (VL>VC)
Positive (+X)
Predominantly Inductive
IlagsV by ϕ
Lagging
Case 2: XL<XC (VL<VC)
Negative (−X)
Predominantly Capacitive
IleadsV by $
\phi
Case 3: XL=XC (VL=VC)
Zero (X=0)
Purely Resistive (Series Resonance)
I is in phase with V (ϕ=0∘)
Unity (cosϕ=1)
(Note: At series resonance, XL=XC⟹2πfrL=2πfrC1, giving the resonant frequency fr=2πLC1, where impedance is minimum Z=R and current is maximum I=V/R.)
Worked Example 1
Problem: A coil having a resistance of 12Ω and an inductance of 0.05 H is connected in series with a 100μF capacitor across a 230 V,50 Hz AC supply. Calculate:
(a) Inductive reactance, capacitive reactance, and total impedance,
(b) RMS current and its phase angle with respect to supply voltage, and
(c) Voltage drops across the coil and across the capacitor.
Solution:
Calculate reactances and total impedance:
XL=2πfL=2π×50×0.05=15.71Ω
XC=2πfC1=2π×50×100×10−61=31.83Ω
Net reactance: X=XL−XC=15.71−31.83=−16.12Ω (capacitive since XC>XL)
Complex impedance: Z=12−j16.12Ω
Magnitude of impedance:
Z=122+(−16.12)2=144+259.85=403.85=20.10Ω
Calculate RMS current (taking V=230∠0∘ V):I=ZV=20.10∠−53.34∘230∠0∘=11.44∠+53.34∘ A
Thus, RMS current is 11.44 A and it leads the supply voltage by 53.34∘.
Calculate voltage across the coil (R and L together) and across the capacitor (C):
Impedance of the coil: Zcoil=R2+XL2=122+15.712=19.77Ω
Voltage across coil: Vcoil=I⋅Zcoil=11.44×19.77=226.17 V
Voltage across capacitor: VC=I⋅XC=11.44×31.83=364.14 V
Answer: (a) XL=15.71Ω,XC=31.83Ω,Z=20.10∠−53.34∘Ω; (b) I=11.44 A (leading by 53.34∘); (c) Vcoil=226.17 V,VC=364.14 V.
Summary
Series RL: Z=R+jXL=R2+XL2∠+ϕ, current lags voltage by ϕ=tan−1(XL/R).
Series RC: Z=R−jXC=R2+XC2∠−ϕ, current leads voltage by ϕ=tan−1(XC/R).
Series RLC: Z=R+j(XL−XC), Z=R2+(XL−XC)2, V=VR2+(VL−VC)2.
Power in AC circuits: Power factor, active, reactive and apparent power
Instantaneous and Average Power in a General AC Circuit
Let the voltage applied across a general single-phase AC circuit and the resulting current be:
v(t)=Vmsin(ωt)andi(t)=Imsin(ωt−ϕ)
where ϕ is the phase angle between voltage and current.
Derivation of Instantaneous and Average Power:
The instantaneous powerp(t) is the product of instantaneous voltage and instantaneous current:
p(t)=v(t)⋅i(t)=VmImsin(ωt)sin(ωt−ϕ)
Using the trigonometric identity 2sinAsinB=cos(A−B)−cos(A+B):
p(t)=2VmIm[cosϕ−cos(2ωt−ϕ)]
Since V=Vm/2 and I=Im/2, we have 2VmIm=VI:
p(t)=VIcosϕ−VIcos(2ωt−ϕ)
The instantaneous power consists of two parts:
A constant part VIcosϕ, which is independent of time.
A pulsating cosine term VIcos(2ωt−ϕ) that oscillates at twice the supply frequency (2f) and whose average value over one complete cycle is zero.
Therefore, the average power (real or active power) P over a complete cycle is:
P=2π1∫02πp(ωt)d(ωt)=VIcosϕ(watts, W)
The Three Types of AC Power
In an AC circuit, power is characterized by three related quantities that form a right-angled triangle called the Power Triangle:
Code
/|
/ |
S = VI / | Q = VI sin(phi) [Reactive Power, VAR]
[VA] / |
/phi |
+-----+
P = VI cos(phi) [Active Power, W]
Active Power / Real Power / True Power (P):
The actual power consumed or dissipated in the resistive part of the circuit that does useful work (converted into heat, light, or mechanical work).
P=VIcosϕ=I2R(Unit: watt, W or kilowatt, kW)
Reactive Power / Quadrature Power (Q):
The power that continuously surges back and forth between the AC source and the magnetic field of inductors or electric field of capacitors without doing net useful work.
Q=VIsinϕ=I2X=I2(XL−XC)(Unit: volt-ampere reactive, VAR or kVAR)
-By convention, an inductive circuit (XL>XC) absorbs positive reactive power (+Q, lagging VAR), whereas a capacitive circuit (XC>XL) supplies reactive power (−Q, leading VAR).
Apparent Power (S):
The product of the RMS voltage V and the RMS current I supplied to the circuit, without considering the phase angle. Electrical equipment such as transformers and AC generators are rated in terms of apparent power (S).
S=VI=I2Z=P2+Q2(Unit: volt-ampere, VA or kilovolt-ampere, kVA)
(Note: Complex Power is written as S=VI∗=P+jQ=S∠ϕ VA.)
Power Factor (cosϕ)
Definitions of Power Factor
The power factor (pf) of an AC circuit can be defined in three equivalent ways:
Cosine of the phase angle between the supply voltage V and supply current I:
Power Factor=cosϕ
Ratio of Resistance to Impedance (from the impedance triangle):
cosϕ=ZR
Ratio of Active Power to Apparent Power (from the power triangle):
cosϕ=Apparent Power (S)Active Power (P)=VIVIcosϕ
Nature and Range of Power Factor:
Since −90∘≤ϕ≤+90∘ for passive circuits, 0≤cosϕ≤1.
Lagging power factor: Occurs in inductive circuits (XL>XC), where current lags voltage.
Leading power factor: Occurs in capacitive circuits (XC>XL), where current leads voltage.
Unity power factor (cosϕ=1): Occurs in purely resistive circuits or RLC circuits at resonance (XL=XC), where ϕ=0∘.
Zero power factor (cosϕ=0): Occurs in pure inductive or pure capacitive circuits (ϕ=±90∘).
Significance of Power Factor:
For a fixed active power P to be delivered at a constant supply voltage V, the line current required is:
I=VcosϕP
If the power factor cosϕ is low, the circuit draws a much larger currentI from the supply to deliver the same real power P. This causes higher I2R copper losses in transmission lines, larger voltage drops, and requires higher kVA ratings of generators and transformers.
Worked Example 1
Problem: A single-phase AC motor takes a current of 20 A from a 230 V,50 Hz supply at a lagging power factor of 0.8. Calculate:
(a) Apparent power in kVA,
(b) Active power in kW,
(c) Reactive power in kVAR, and
(d) Resistance and inductive reactance of the motor (modeled as a series RL circuit).
Solution:
Given data:V=230 V, I=20 A, cosϕ=0.8 (lagging).
Phase angle: ϕ=cos−1(0.8)=36.87∘
sinϕ=sin(36.87∘)=0.6
(a) Apparent power (S):S=VI=230×20=4600 VA=4.6 kVA
(b) Active power (P):P=VIcosϕ=4600×0.8=3680 W=3.68 kW
(c) Reactive power (Q):Q=VIsinϕ=4600×0.6=2760 VAR=2.76 kVAR
Problem: A voltage v(t)=2002sin(314t+20∘) V applied across an AC circuit produces a current i(t)=102sin(314t−10∘) A. Find the phase angle, power factor, active power, reactive power, and apparent power.
Solution:
Extract RMS values and phase angles:
V=200 V, ϕv=+20∘
I=10 A, ϕi=−10∘
Calculate phase difference (ϕ) and power factor:ϕ=ϕv−ϕi=20∘−(−10∘)=30∘(current lags voltage by 30∘)Power factor=cos30∘=0.866 (lagging)
Calculate S, P, and Q:
Apparent power: S=VI=200×10=2000 VA=2 kVA
Active power: P=VIcos30∘=2000×0.866=1732 W=1.732 kW
Reactive power: Q=VIsin30∘=2000×0.5=1000 VAR=1 kVAR
Answer:ϕ=30∘, pf=0.866 (lagging), P=1732 W, Q=1000 VAR, S=2000 VA.
Summary
Active power:P=VIcosϕ=I2R (W).
Reactive power:Q=VIsinϕ=I2X (VAR).
Apparent power:S=VI=I2Z=P2+Q2 (VA).
Power factor:cosϕ=ZR=SP.
Three-phase AC systems: Generation, advantages and balanced connections
Syllabus: Three-Phase AC Systems
Generation of three-phase voltages, advantages of three-phase systems
Star and delta connections (balanced only)
Relation between line and phase voltages, line and phase currents - numerical problems
Generation of Three-Phase Voltages
A three-phase AC system consists of three identical single-phase AC voltage sources of the same frequency and same amplitude, displaced from one another in phase by 120∘ electrical (2π/3 radians).
Principle of Generation:
Consider three identical armature coils R-R′, Y-Y′, and B-B′ (representing the Red, Yellow, and Blue phases) mounted on the stator of an alternator such that their magnetic axes are physically displaced from one another in space by 120∘.
When a magnetic rotor is rotated at a constant angular velocity ω inside these three coils, sinusoidal emfs of equal maximum value Em and equal frequency f=ω/(2π) are induced in all three coils.
Because of the 120∘ spatial displacement, the emf in phase Y reaches its positive peak 120∘ after phase R, and the emf in phase B reaches its positive peak 120∘ after phase Y (i.e., 240∘ after phase R, or 120∘ before phase R).
Instantaneous and Phasor Equations (for RYB Phase Sequence):
Important Property: At every instant of time, the algebraic sum of the three balanced instantaneous three-phase voltages is zero, and their phasor sum is also zero:
eR(t)+eY(t)+eB(t)=0andER+EY+EB=0
Phase Sequence:
The order in which the voltages in the three phases attain their positive maximum values is called the phase sequence. The standard (positive) phase sequence is R→Y→B; reversing the direction of rotation (or interchanging any two line leads) gives the reverse (negative) sequence R→B→Y.
Advantages of Three-Phase Systems over Single-Phase Systems
Constant Instantaneous Power and Uniform Torque: In a single-phase system, instantaneous power pulsates at twice the supply frequency (2f), causing vibration in motors. In a balanced three-phase system, the total instantaneous power ptotal(t)=pR(t)+pY(t)+pB(t)=3VphIphcosϕ is completely constant at every instant, resulting in smooth, pulsation-free torque in three-phase motors.
Higher Output Rating for a Given Frame Size: A three-phase alternator or motor has about 1.5 times the power output of a single-phase machine of the same physical frame size and weight.
Economy in Transmission Conductor Material: To transmit the same amount of power over a fixed distance at the same voltage and power loss, a three-phase system requires only about 75% of the conductor weight (copper/aluminium) required by a single-phase system.
Self-Starting Capability of Three-Phase Motors: Three-phase currents flowing in three spatially displaced windings produce a uniform rotating magnetic field (RMF), making three-phase induction motors inherently self-starting without auxiliary starting windings or capacitors.
Availability of Two Voltages (in 3-Phase, 4-Wire Star System): A star-connected system with a neutral wire provides two voltage levels simultaneously: phase voltage (230 V) between any line and neutral for domestic single-phase loads, and line voltage (3×230≈400 V) between any two lines for industrial three-phase loads.
Balanced Three-Phase System and Basic Definitions
Balanced Supply and Balanced Load: Three-phase voltages are balanced if they are equal in magnitude and displaced by 120∘ in phase. A three-phase load is balanced if the impedances in all three phases are identical in both magnitude and phase angle (ZR=ZY=ZB=Zph∠ϕ).
Phase Voltage (Vph): The voltage across any single phase winding or single load impedance branch.
Line Voltage (VL): The voltage measured between any two of the three line conductors (VRY, VYB, or VBR).
Phase Current (Iph): The current flowing through any single phase winding or single load impedance branch.
Line Current (IL): The current flowing through any of the three external transmission line conductors (IR, IY, or IB).
1. Balanced Star (Wye, Y) Connection
In a Star (Y) connection, the similar ends (starting ends or finishing ends) of the three phase impedances are joined together at a common point N called the neutral point (or star point), and the other three ends are connected to the three line conductors R, Y, and B.
Code
Line R ------>----+ I_L = I_ph
|
[Z_ph] (V_ph = V_RN)
|
Neutral N --------*-------------------- (Neutral Wire)
/ \
(V_YN) [Z_ph] / \ [Z_ph] (V_BN)
/ \
Line Y ------>+ +<------ Line B
Derivation of Line-to-Phase Relations in Star Connection:
Current Relation:
Since each line conductor is connected directly in series with its respective phase winding, the line current is identical to the phase current:
IL=Iph(In a balanced 4-wire star system, the neutral current is IN=IR+IY+IB=0.)
Voltage Relation:
Let the balanced phase voltages with respect to the neutral N be:
VRN=Vph∠0∘,VYN=Vph∠−120∘,VBN=Vph∠+120∘
Applying KVL between line R and line Y, the line voltage VRY (potential of R with respect to Y) is the phasor difference between VRN and VYN:
VRY=VRN−VYN=VRN+(−VYN)
On the phasor diagram, −VYN has magnitude Vph at an angle of −120∘+180∘=+60∘ with respect to VRN.
Therefore, the angle between VRN (0∘) and −VYN (+60∘) is α=60∘.
Using the parallelogram law of vector addition for two equal phasors of length Vph separated by 60∘:
VL=VRY=Vph2+Vph2+2VphVphcos60∘=Vph2+Vph2+2Vph2(0.5)=3Vph2VL=3Vph≈1.732Vph
Also, the resultant phasor VRY bisects the 60∘ angle between VRN and −VYN, so each line voltage leads its corresponding phase voltage by 30∘:
VRY=3Vph∠+30∘,VYB=3Vph∠−90∘,VBR=3Vph∠+150∘
2. Balanced Delta (Mesh, Δ) Connection
In a Delta (Δ) connection, the finishing end of one phase impedance is connected to the starting end of the next phase impedance to form a closed triangular loop, and the three line conductors R, Y, and B are connected to the three junction points.
Code
Line R (I_R) ---------->---------*
/ \
/ \
(I_BR) [Z_ph] / \ [Z_ph] (I_RY = I_ph)
/ \
Line B (I_B) ------>--------*---------*--------<------ Line Y (I_Y)
[Z_ph]
(I_YB)
Derivation of Line-to-Phase Relations in Delta Connection:
Voltage Relation:
Since each phase impedance is connected directly across a pair of line conductors, the line voltage is equal to the phase voltage:
VL=Vph
Current Relation:
Let the three balanced phase currents inside the delta loop be:
IRY=Iph∠0∘,IYB=Iph∠−120∘,IBR=Iph∠+120∘
Applying Kirchhoff's Current Law (KCL) at junction R:
IR+IBR=IRY⟹IR=IRY−IBR=IRY+(−IBR)
On the phasor diagram, −IBR has magnitude Iph at an angle of +120∘−180∘=−60∘ with respect to IRY (0∘).
The angle between IRY and −IBR is 60∘.
Using the parallelogram law of vector addition for two equal phasors of magnitude Iph separated by 60∘:
IL=IR=Iph2+Iph2+2IphIphcos60∘=3Iph2IL=3Iph≈1.732Iph
Also, the line current IR bisects the angle between IRY (0∘) and −IBR (−60∘), so each line current lags behind its corresponding phase current by 30∘:
IR=3Iph∠−30∘
Summary of Star and Delta Relations
Star (Y) connection:IL=Iph and VL=3Vph.
Delta (Δ) connection:VL=Vph and IL=3Iph.
Power in balanced three-phase circuits and worked problems
Power Expressions in a Balanced Three-Phase Circuit
In any balanced three-phase circuit (whether connected in Star or Delta), each of the three identical phases has phase voltage Vph, phase current Iph, and phase angle ϕ between Vph and Iph (where cosϕ=Rph/Zph).
Therefore, the active power consumed per phase is Pph=VphIphcosϕ, and the total three-phase active powerP is three times the single-phase power:
P=3Pph=3VphIphcosϕ(watts, W)
Expressing Three-Phase Power in Terms of Line Quantities (VL and IL):
For a Balanced Star (Y) Connection:
Substitute Vph=3VL and Iph=IL:
P=3(3VL)ILcosϕ=3VLILcosϕ(W)
For a Balanced Delta (Δ) Connection:
Substitute Vph=VL and Iph=3IL:
P=3VL(3IL)cosϕ=3VLILcosϕ(W)
Thus, the expressions for Total Active, Reactive, and Apparent Power in terms of line voltage VL and line current IL are identical for both Star and Delta connections:
Total Active Power (P):P=3VphIphcosϕ=3VLILcosϕ=3Iph2Rph(W)
Total Reactive Power (Q):Q=3VphIphsinϕ=3VLILsinϕ=3Iph2Xph(VAR)
Total Apparent Power (S):S=3VphIph=3VLIL=P2+Q2(VA)
(Important Note: In all these formulas, ϕ is always the phase angle between the phase voltage Vph and the phase current Iph, i.e., cosϕ=Rph/Zph, NOT the angle between VL and IL.)
Comparison: Balanced Star vs. Balanced Delta Connection
Parameter
Star (Y) Connection
Delta (Δ) Connection
Voltage relation
VL=3Vph
VL=Vph
Current relation
IL=Iph
IL=3Iph
Phase current (Iph)
Iph=3ZphVL
Iph=ZphVL
Line current (IL)
IL(star)=3ZphVL
IL(delta)=Zph3VL=3IL(star)
Total Active Power (P)
P=3VLILcosϕ
P=3VLILcosϕ=3Pstar (for same Zph and VL)
Neutral point
Available (permits 3-phase 4-wire supply)
Not available (3-phase 3-wire only)
Worked Example 1 (Star-Connected Load)
Problem: Three identical coils, each having a resistance of 15Ω and an inductance of 0.04 H, are connected in star across a 400 V,50 Hz, three-phase balanced AC supply. Calculate:
(a) Phase voltage,
(b) Impedance and power factor of each phase,
(c) Phase current and line current, and
(d) Total active power, reactive power, and apparent power absorbed by the load.
Solution:
Identify given data:VL=400 V, f=50 Hz, Rph=15Ω, Lph=0.04 H (Star connected).
(a) Calculate phase voltage (Vph):Vph=3VL=1.732400=230.94 V
(b) Calculate phase impedance (Zph) and power factor (cosϕ):
Inductive reactance per phase:
Xph=2πfLph=2π×50×0.04=12.57Ω
Impedance per phase:
Zph=Rph2+Xph2=152+12.572=225+158.0=383.0=19.57Ω
Power factor:
cosϕ=ZphRph=19.5715=0.7665 (lagging)ϕ=cos−1(0.7665)=39.96∘,sinϕ=ZphXph=19.5712.57=0.6423
(c) Calculate phase current (Iph) and line current (IL):Iph=ZphVph=19.57230.94=11.80 A
For a star connection:
IL=Iph=11.80 A
(d) Calculate total P, Q, and S:
Total Active Power:
P=3VLILcosϕ=1.732×400×11.80×0.7665=6266 W=6.266 kW
Total Reactive Power:
Q=3VLILsinϕ=1.732×400×11.80×0.6423=5251 VAR=5.251 kVAR
Total Apparent Power:
S=3VLIL=1.732×400×11.80=8175 VA=8.175 kVA
Problem: If the same three coils of Worked Example 1 (Rph=15Ω, Lph=0.04 H) are reconnected in delta across the same 400 V,50 Hz three-phase supply, calculate: (a) Phase voltage, (b) Phase current, (c) Line current, and (d) Total active power consumed.
Solution:
From Worked Example 1, per-phase impedance and power factor remain unchanged:
Zph=19.57Ωandcosϕ=0.7665 (lagging)
(a) Phase voltage (Vph) in Delta:Vph=VL=400 V
(b) Phase current (Iph):Iph=ZphVph=19.57400=20.44 A
(c) Line current (IL):IL=3Iph=1.732×20.44=35.40 A(Notice that IL(delta)=35.40 A=3×11.80 A=3IL(star).)
(d) Total Active Power (P):P=3VLILcosϕ=1.732×400×35.40×0.7665=18.80 kW(Notice that Pdelta=18.80 kW=3×6.266 kW=3Pstar.)
Problem: A balanced three-phase delta-connected load draws a total active power of 12 kW at a lagging power factor of 0.8 from a 415 V,50 Hz three-phase supply. Find the line current, phase current, and the resistance and reactance of each phase of the load.
Solution:
Calculate line current (IL):P=3VLILcosϕ⟹IL=3VLcosϕP=1.732×415×0.812000=20.87 A
Calculate phase current (Iph) for Delta:Iph=3IL=1.73220.87=12.05 A
Calculate phase impedance (Zph), resistance (Rph), and reactance (Xph):
For Delta, Vph=VL=415 V.
Zph=IphVph=12.05415=34.44Ω
Rph=Zphcosϕ=34.44×0.8=27.55Ω
Since cosϕ=0.8, sinϕ=0.6:
Xph=Zphsinϕ=34.44×0.6=20.66Ω
Answer:IL=20.87 A, Iph=12.05 A, Rph=27.55Ω, Xph=20.66Ω.
Summary
In both Star and Delta balanced 3-phase circuits: P=3VLILcosϕ, Q=3VLILsinϕ, and S=3VLIL.
When three identical impedances are switched from Star to Delta across the same line voltage VL, both the line current drawn and the total power consumed increase by a factor of 3 (IL(Δ)=3IL(Y) and PΔ=3PY).
Suggested reading
Textbooks
D. P. Kothari and I. J. Nagrath, Basic Electrical Engineering, Tata McGraw Hill, 4th ed., 2019.
J. J. Cathey and Syed A. Nasar, Schaum's Outline of Basic Electrical Engineering, Tata McGraw Hill, 3rd ed., 2010.
D. P. Kothari and I. J. Nagrath, Basic Electrical and Electronics Engineering, McGraw Hill, 2nd ed., 2020.
Reference Books
D. C. Kulshreshtha, Basic Electrical Engineering, Tata McGraw Hill, 2nd ed., 2019.
V. Del Toro, Electrical Engineering Fundamentals, Pearson Education, 2nd ed., 2019.
T. K. Nagsarkar and M. S. Sukhija, Basic Electrical Engineering, Oxford Higher Education, 3rd ed., 2017.